Sign In | Join Free | My burrillandco.com
Home > P+F Sensors >

Terminals 14 15 Universal Temperature Converter KFD2-UT2-1

    Buy cheap Terminals 14 15 Universal Temperature Converter KFD2-UT2-1 from wholesalers
     
    Buy cheap Terminals 14 15 Universal Temperature Converter KFD2-UT2-1 from wholesalers
    • Buy cheap Terminals 14 15 Universal Temperature Converter KFD2-UT2-1 from wholesalers
    • Buy cheap Terminals 14 15 Universal Temperature Converter KFD2-UT2-1 from wholesalers

    Terminals 14 15 Universal Temperature Converter KFD2-UT2-1

    Ask Lasest Price
    Brand Name : P+F
    Model Number : KFD2-UT2-1
    Certification : CE
    Price : negotiable
    Payment Terms : T/T
    Supply Ability : 100pcs per month
    Delivery Time : on request
    • Product Details
    • Company Profile

    Terminals 14 15 Universal Temperature Converter KFD2-UT2-1

    Universal Temperature Converter KFD2-UT2-1


    1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Field device: resistance thermometer, Field device [2]: Thermocouple


    Technical Data


    General specifications

    Signal type

    Analog input

    Functional safety related parameters

    Safety Integrity Level (SIL)

    SIL 2

    Supply

    Connection

    terminals 14+, 15- or power feed module/Power Rail

    Rated voltage

    20 ... 30 V DC

    Ripple

    within the supply tolerance

    Power dissipation

    ≤ 0.98 W

    Power consumption

    max. 0.98 W

    Interface

    Programming interface

    programming socket

    Input

    Connection side

    field side

    Connection

    terminals 1, 2, 3, 4

    RTD

    type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995)
    type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94)
    type Cu10, Cu50, Cu100 (P50353-92)
    type Ni100 (DIN 43760)


    Measuring current

    approx. 200 µA with RTD


    Types of measuring

    2-, 3-, 4-wire connection


    Lead resistance

    max. 50 Ω per line


    Measurement loop monitoring

    sensor breakage, sensor short-circuit

    Thermocouples

    type B, E, J, K, N, R, S, T (IEC 584-1: 1995)
    type L (DIN 43710: 1985)
    type TXK, TXKH, TXA (P8.585-2001)


    Cold junction compensation

    external and internal


    Measurement loop monitoring

    sensor breakage

    Potentiometer

    0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)

    Voltage

    selectable within the range -100 ... 100 mV

    Input resistance

    ≥ 1 MΩ (-100 ... 100 mV)

    Output

    Connection side

    control side

    Connection

    output I: terminal 7: source (-), sink (+), terminal 8: source (+), terminal 9: sink(-)

    Output

    Analog current output


    Current range

    0 ... 20 mA or 4 ... 20 mA


    Fault signal

    downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)


    Source

    load 0 ... 550 Ω
    open-circuit voltage ≤ 18 V


    Sink

    Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V,
    series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage.
    The maximum value of the resistance is (V - 5)/0.0215 Ω.

    Transfer characteristics

    Deviation



    After calibration

    Pt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection))
    thermocouple: ± (0.05 % of measurement value in °C + 0.1 % of span + 1 K (1.2 K for types R and S)) , includes ± 0.8 K fault of the cold junction compensation (CJC)
    mV: ± (50 µV + 0.1 % of span)
    potentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes faults due to lead resistance))


    Influence of ambient temperature

    Pt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*)
    thermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*)), influence of cold junction compensation (CJC) included
    mV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔTamb*)
    potentiometer: ± 0.006 % of span/K ΔTamb*)
    *) ΔTamb = ambient temperature change referenced to 23 °C (296 K)


    Influence of supply voltage

    < 0.01 % of span


    Influence of load

    ≤ 0.001 % of output value per 100 Ω

    Reaction time

    worst case value (sensor breakage and/or sensor short circuit detection enabled)
    mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s

    Galvanic isolation

    Input/Other circuits

    basic insulation according to IEC 61010-1, rated insulation voltage 300 Veff

    Output/supply, programming input

    functional insulation, rated insulation voltage 50 V AC
    There is no electrical isolation between the programming input and the supply.
    The programming cable provides galvanic isolation so that ground loops are avoided.

    Indicators/settings

    Display elements

    LEDs

    Configuration

    via PACTware

    Labeling

    space for labeling at the front

    Directive conformity

    Electromagnetic compatibility



    Directive 2014/30/EU

    EN 61326-1:2013 (industrial locations)

    Conformity

    Electromagnetic compatibility

    NE 21:2006

    Degree of protection

    IEC 60529:2001

    Ambient conditions

    Ambient temperature

    -20 ... 60 °C (-4 ... 140 °F)

    Mechanical specifications

    Degree of protection

    IP20

    Connection

    screw terminals

    Mass

    approx. 130 g

    Dimensions

    20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2


    Height

    119 mm


    Width

    20 mm


    Depth

    115 mm

    Mounting

    on 35 mm DIN mounting rail acc. to EN 60715:2001


    Related Models:


    KCD2-SCD-EX1

    KFU8-UFT

    KCD2-STC-EX1.20

    K-HM26-2M-261533

    KFD2-SR2-Ex1.W.LB

    NBB15-U1-E2

    KFD2-SR2-2.W.SM

    NBB1,5-5GM25-E2

    KFD2-SR2-Ex2.W.SM

    NBB1,5-5GM25-E2-V3

    KFD2-SR2-Ex2.2S

    NBB1,5-F79-E0

    KFD2-SR2-2.2S

    NBB1,5-F79-E2

    KFA6-DWB-EX1.D

    NBB15-U1-Z2

    KFA6-SR2-Ex2.W

    NBB5-18GM50-E2-V1

    KFA6-SR-2.3L.FA

    NBB15-30GM30-E2-V1

    KFA6-ER-1.5

    NBB15-30GM50-A2-V1

    KFA6-ER-1.6

    NBB15-30GM50-E2

    KFA6-ER-1.W.LB

    NBB15-30GM50-E2-M

    KFA6-ER-2.W.LB

    NBB15-30GM50-E2-V1

    KFA6-ER-Ex1.W.LB

    NBB15-30GM50-E2-V1-M

    KFA6-SR-2.3L.FA

    NBB8-18GM30-E2

    KFA6-STR-1.24.4

    NBB8-18GM30-E2-V1

    KFD0-CS-Ex1.50P

    NBB8-18GM60-A2-V1

    KFD2-SH-Ex1.T.OP

    NJ4-12GK-SN

    KFD2-SL2-EX2.B

    NJ5-18GK-N

    KFD2-SR2-EX1.W

    NJ5-18GK-N-150

    KFD2-SR2-Ex2.W

    NJ5-18GM-N

    KFD2-STC5-1.2O

    NJ8-18GK-N

    KFD2-STC5-Ex1

    RD0-FB-EX4

    KFD2-STC5-Ex1.H

    RD0-TI-Ex8.FF.*

    HIC2031

    Z787.F


    Quality Terminals 14 15 Universal Temperature Converter KFD2-UT2-1 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: SC Automation Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)